Advanced line filters for clean, efficient compressed air systems
The LF(e) 9–490 line filter family combines robust housings with high‑performance filter elements to deliver clean compressed air across flows from approximately 0.9 to 49 m³/min. Multi‑layer glass‑fibre media capture particles and aerosols with high efficiency while maintaining low flow resistance, supporting consistent air quality throughout the system.
Durable epoxy‑sealed end caps, dual O‑ring interfaces and integrated condensate drainage ensure reliable, leak‑free operation over long service intervals. Multiple filtration grades, including particle, fine dust, coalescing oil removal and vapour adsorption, allow users to meet defined ISO air‑purity requirements without oversizing equipment.
The LF(e) 9–490 range is designed for fast, safe and predictable maintenance. Filter elements can be replaced easily, with O‑ring sealing ensuring correct positioning and eliminating leakage risks after service. Clear installation orientation and accessible drain components simplify routine inspections.
Maintaining clean upstream air, correct filter sizing and timely element replacement helps extend service life and ensures consistent ISO‑compliant air quality. Simple maintenance routines reduce downtime while supporting long‑term reliability of the compressed air system.
Low pressure drop and efficient filter media design reduce the energy required to deliver clean compressed air, contributing directly to lower operating costs. By preventing dust, oil and vapours from reaching downstream equipment, LF(e) filters help reduce wear on valves, actuators and instrumentation.
Multiple filtration grades allow users to tailor air purity to specific applications without unnecessary oversizing. Rugged housings, reliable drainage and long element life combine to deliver a low total cost of ownership and dependable system protection.
Technical information
| Model | Nominal Capacity | Dimensions | Connection Size | Weight | ||
|---|---|---|---|---|---|---|
| l/min | cfm | m3/h | L×W×H(mm) | G | Kg | |
| LF(e)9 | 720 | 25 | 43 | 90×79×276 | 3/4" | 0.77 |
| LF(e)18 | 1500 | 53 | 90 | 90×79×276 | 3/4" | 0.78 |
| LF(e)25 | 2100 | 74 | 126 | 90×79×331 | 3/4" | 0.89 |
| LF(e)35 | 3000 | 106 | 180 | 110×100×380 | 1" | 1.4 |
| LF(e)60 | 4800 | 170 | 288 | 126×100×435 | 1 1/2" | 1.68 |
| LF(e)105 | 8400 | 297 | 504 | 155×131×565 | 2" | 3.29 |
| LF(e)140 | 11400 | 403 | 684 | 155×131×600 | 2" | 3.63 |
| LF(e)175 | 15600 | 551 | 936 | 155×131×645 | 2" | 3.86 |
| LF(e)260 | 21600 | 763 | 1296 | 193×171×767 | 2 1/2" | 6.14 |
| LF(e)380 | 31500 | 1112 | 1890 | 210×196×920 | 3" | 8.78 |
| LF(e)490 | 40500 | 1430 | 2430 | 210×196×1090 | 3" | 10.33 |
Unit performance measured according to ISO 1217, Annex C, ed.4 2009.
| Inlet Air Pressure Correction Factor | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| Inlet Air Pressure (bar) |
5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 |
| Correction Factor | 0.9 | 0.97 | 1 | 1.03 | 1.06 | 1.08 | 1.1 | 1.12 | 1.13 |
| Filter Grade | Filter Type | Dust Removal Efficiency | Oil Removal Concentration |
Oil Removal Efficiency |
Initial Pressure Drop | ISO8573-1 Cleanliness Class |
|||
|---|---|---|---|---|---|---|---|---|---|
| bar | |||||||||
| G | Oil Removal Filter | 99.87% (@0.01μm) | 99.97% (@1μm) | 99.81% (@0.1μm) | ≤0.1 | 99% | 0.12 | Class 2-3 | |
| C | High-Precision Oil Filter | 99.992% (@0.01μm) | 99.999% (@1μm) | 99.97% (@0.06μm) | ≤0.01 | 99.90% | 0.14 | Class 1-2 | |
| V | Oil Vapor Removal Filter | N/A | N/A | N/A | ≤0.003 | N/A | 0.16 | Class 1 | |
LF(e) 9-490
Download the product brochure
Download the brochure to explore the full details of this Liutech range. Inside, you'll find key product features, technical specifications, available configurations, and insights to help you select the right solution for your compressed air requirements.
Get in touch with us
Contact us to buy your next stationary compressor today
Not sure which compressor to buy?
Contact us for product recommendations, and tailored quotations designed around your operational requirements.